Smartscan Incorporated 

 32841 Eight Mile Road 

 Livonia, MI  48152

Ph: (248) 477-2900   Fax: (248) 477 -7453

Safety Modules

Many safety devices send an electronic signal indicating the state of the device. However most machines require discontinuity in the safety circuit to initiate machine shut down or stoppage of hazardous motion. Smartscan's multi-function modules provide this vital interface.

These safety modules incorporate dual, failsafe, monitored relays that can be applied to the machines stopping circuit initiating a shutdown signal. Modules for single devices, and multiple devices are available. Other options including muting functions, reset capabilities and external device monitoring.

(Click on the high-lighted text of the Safety module of interest)

 

Safety Module: MFU-1: Single Light Curtain Input

Safety Module: MFU-2: Dual Light Curtain Input + E-Stop

Safety  Module: MFU-M1: Single Light Curtain Input with Mute + E-Stop

 

Safety Module: MFU-1: Single Light Curtain Input

   

    MFU-1: Specifications, Dimensions & Controls

Features

  • Dual safety inputs for connecting the light curtain

  • Safety monitored output relays.  Contacts rated at 250V AC, 4A

  • Auxiliary electronic output for status indication etc.

  • Reset function

  • External Device Monitor (EDM)

  • LED status indicators

  • Din rail mounting - 70mm enclosure

Return to Safety Modules Index

Safety Module: MFU-2: Dual Light Curtain Input

    MFU-2:Specifications, Dimensions & Controls 

Features

  • Two dual safety inputs for connecting up to 2 light curtains

  • Dual inputs for connecting the emergency stop circuit

  • Safety monitored output relays.  Contacts rated at 250V AC, 2A

  • Auxiliary electronic output switches for status indication etc

  • Reset function

  • External Device Monitoring (EDM)

  • LED indicators for all inputs and outputs

  • DIN rail mounting – 70mm enclosure

  • Automatic self testing

  • Simultaneous monitoring between related channels

  • Built to BS EN 954-1 Category 4

Return to Safety Modules Index

Safety Module: MFU-M1: Single Light Curtain Input with Mute.

MFU-M1: Specification, Dimensions & Controls

Features

  • Dual safety inputs for connecting the light curtain

  • Dual inputs for muting the light curtain

  • Dual inputs for connecting the emergency stop circuit

  • Safety monitored output relays.  Contacts rated at 250V AC, 2A

  • Auxiliary electronic output for mute indication

  • Reset function

  • External Device Monitoring (EDM)

  • LED indicators for all inputs and outputs

  • DIN rail mounting – 70mm enclosure

  • Automatic self testing

  • Monitoring between related channels  

Return to Safety Modules Index

 

                                            

Master Card Logo.jpg (66282 bytes)Visa Logo.jpg (78649 bytes)

Products    Distributors    Applications    Sizing   Contact US 

If you have any problems or comments concerning this website

contact: webmaster@smartscaninc.com

The information and drawings contained herein are the sole property of Smartscan Incorporated.  The information on this website is subject to change without notice. Smartscan Incorporated shall not be liable for any errors contained herein for incidental or consequential damages in connection with the performance or use of this material.