| Dual Light Curtain Module | MFU-2 Specifications | MFU-2 Dimensions |
|
Status Indicators Inputs - Green LED ON when input is ON Wiring Information Terminals A1 and A2 – Power supply input - Connect a suitably stabilized 24V DC power supply
Terminals A3 and A4 – External device monitor (EDM) -
Normally closed switch contacts,
in To reset from a lockout condition it is necessary to remove the 24V DC supply from the MFU and
If the EDM circuit is
not used it is necessary to link terminals A3 to A4 otherwise the
system will go Terminals A5 and A6 – Safety
output 1 switch contact - Connect terminals A5 and A6 to one
channel of a machine’s stop circuitry. For example, via an external power-switching relay or
directly
Terminals A7 and A8 – Safety output 2 switch contact -
Connect terminals A7 and A8 to one
channel
of a machine’s stop circuitry. For example, via an external power-switching relay or
directly If a single channel safety circuit is used link terminals A6 and A7. Terminals A5 and A8 are then connected to the machine’s safety circuit. Connecting in this way links safety output switch 1 and safety output switch 2 in a series configuration. Terminal A9 – No connection
Terminal A10 – Auxiliary electronic switching output 1 - The Auxiliary switching output
should
Terminal A11 – Auxiliary electronic switching output 2 -
The Auxiliary switching output
should Auxiliary outputs 1 and 2 both energize when safety output switches 1 and 2
energize and both de-energize when the safety outputs de-energize. Auxiliary outputs ON = 24V DC and OFF = 0V DC. Terminal A12 – Reset - If the MFU is required to be in the latch mode a suitable switch should be connected between terminal A12 and the 24V DC supply. If the safety output relays de-energize a depression of the switch is required to re-energize the output switches to an ON condition. The MFU’s safety output switches will only re-energize when the reset switch is depressed and then released. If the MFU is
required to operate in an automatic reset condition do not connect a
switch to Terminal B1 and B2 – light curtain 1 inputs (OSSD1 and OSSD2) - Connect the electronic output switches (OSSD1 and OSSD2) of a 1000 Series light curtain to terminals B1 and B2 respectively.
Note: An internal
circuit monitors disparity between the two input channels. If the inputs do not Terminal B3 and B4 – light curtain 2 inputs (OSSD1 and OSSD2) - Connect the electronic output switches (OSSD1 and OSSD2) of a 1000 Series light curtain to terminals B3 and B4 respectively Note:
An internal
circuit monitors disparity between the two input channels. If the inputs do not
Important: If either terminal B1/B2 or, B3/B4 are not used; for example, if only one light curtain is employed for a particular application, it is necessary to link the unused input terminals to the 24V DC supply. If not the MFU’s output switches will not energize. Terminals B5/B6
and B7/B8 – dual channel emergency stop circuit - Connect one
channel of Note:
An internal
circuit monitors for short circuits and switching disparity between
the two input channels. If the inputs do not switch together (within 100ms of each other)
the system will go into Important: If the emergency stop inputs are not used it is necessary to link terminals B5 to B6 and terminals B7 to B8. If not the safety output switches will not energize. Terminals B9 and B11 – 24V DC supply - Additional + 24V DC outputs for connecting to the light curtains etc. Terminals B10 and B12 – 0V DC supply - Additional 0V DC outputs for connecting to the light curtains etc. |