Smartscan Safety Light Curtain T4HD: Dipswitch (Learned) Settings

Learned Settings Mode 

Learned Mode is the mode that allows the user to access the following functions:
 (To view the functions available in the learned mode scroll down)
  1. Fixed Beam
  2. Partial Muting
  3. Press Mode
  4. Mute disparity /Mute delay OFF modes
  5. Clear (All Learned functions)
Picture
Entering the Learned Mode

The following steps are required to enter the Learned Mode.
  • Step 1: Turn Power OFF
  • Step 2: Select any learned mode dip switch setting as in the diagram below
  • Step 3: Turn Power ON
Once power turns ON. The all LED’s in the Receiver column (RX) will turn ON steady. At this time the safety outputs (OSSD’s will remain OFF). The light curtain is now in Learned Mode.
Picture
Picture
Picture

Exit Learned Mode

To exit the Learned Mode apply one of the three start up modes:
  • Automatic Restart
  • Manual Restart
  • Restart Interlock
Then cycle power(Turn power OFF then ON).
Picture
Picture
There are currently 6 functions available in the learned mode. A brief description of the function is given below each accessible function.(Click on the underlined text or the picture for more details)
Picture
Fixed Beam Blanking
Deselecting specific beams in the light curtains sensing region.
Picture
N/A
Picture
Mute Timer Mode 2
Mute Disparity - 2 Secs
Mute Off - 1 Secs.

Picture
Mute Timer Mode 3
Mute Disparity - 4 Sec.
Mute Off - 2 Secs.

Picture
Mute Timer Mode 4
Mute Disparity - 250 msec.
Mute Off - 0 Secs.

Picture
Partial Muting
Muting a defined area in the sensing region
Picture
N/A
Picture
Clear
Clears all the functions activated in the learned mode.
The information and drawings contained herein are the sole property of Smartscan Incorporated. The informationon this website is subject to change without notice. Smartscan Incorporated shall not be liable for any errors contained herein for incidental or consequential damages in connection with the performance or use of this material.