Smartscan Safety Light Curtain SG: Mute Timer Mode 3 (Learned Mode)

Mute timer mode 3 has a mute disparity of 4 seconds with a mute delay off of 2 seconds. Mute disparity is the time period that the mute inputs (Mute 1 & Mute 2) have to agree (Mute inputs both ON). Once either of the mute inputs is deactivated (turned OFF) the system will remain muted for an additional 2 seconds in mute timer mode 3.

The default disparity is 2 seconds and 2 second mute delay off.
 
Picture
This feature is available in the Learned Mode. Configure mute timer mode 3 using the following steps:
  1. Turn power OFF
  2. Configure dipswitches as in the diagram to the left
  3. Turn power ON, wait until ALL LED's illuminate in receiver (Rx) column.
  4. Apply Exit Learned Mode procedure. If done with learned mode or apply another feature.
The information and drawings contained herein are the sole property of Smartscan Incorporated. The informationon this website is subject to change without notice. Smartscan Incorporated shall not be liable for any errors contained herein for incidental or consequential damages in connection with the performance or use of this material.